The reported problem was that the lights were not working. The inspection found a disconnected wire in the hallway switches, creating a poor connection. The switch box also had two broken mounting screws, and the electrical panel was not mounted correctly in the wall. Two kitchen receptacles needed work because the tile openings were not cut properly.
PTX's approach
The hallway switch-box wires were stripped back and re-terminated. The broken mounting screws were drilled out, the holes were tapped, and the screwless cover was remounted. PTX shut off the power before unmounting the panel, disconnected some rigid conduit, removed the drywall interfering with the box and moved the panel higher in the wall. The kitchen receptacles were fitted with covers using a specialized drill bit, and an L16 connector was installed for the dishwasher.
The recorded result
The hallway switch wiring was re-terminated and the switchless cover was remounted after the damaged mounting points were repaired. The panel was moved into position higher in the wall. The kitchen receptacle covers were installed, and the dishwasher connection received an L16 connector. The recorded electrical work was completed as part of this invoiced emergency response.
What this job helps another property owner consider
When lights stop working, the cause may be within a switch connection rather than the light itself. This job also shows why an emergency inspection can identify related mounting, receptacle and appliance-connection work that should be addressed as part of the same visit.
Frequently asked questions
Questions property decision-makers ask
What was causing the hallway lights not to work in this Vancouver job?
The recorded finding was a disconnected wire in the hallway switches, which caused a poor connection. The wires were stripped back and re-terminated.