Documented field work
Installation details and completed work

The need
The outlet was severely damaged by overheating. The recorded notes link the problem to wires that had been terminated using backstab connections. An air conditioner had previously been plugged into the outlet, but the equipment itself was not identified as the direct problem.
PTX's approach
PTX replaced the damaged receptacle with a 20A TR Decora receptacle. The wires were terminated around the screws rather than using the backstab connections, and the terminals were taped. The switch was also checked and found to be full of paint, which was removed before testing.
The recorded result
After the replacement and correction of the terminations, PTX tested the outlet. The job notes record that the outlet was working properly. No additional equipment replacement or panel upgrade is recorded for this service call.
What this job helps another property owner consider
If an outlet has overheated or shows damage, the receptacle itself may not be the only point worth examining. This job shows the value of checking how the wires are terminated and whether nearby switches or outlets have been affected by paint or other conditions before the work is considered finished.
Frequently asked questions
Questions property decision-makers ask
What was replaced during this Vancouver electrical service call?
PTX replaced the severely damaged outlet with a 20A TR Decora receptacle and corrected the wire terminations from backstab connections to screw terminals.