Documented field work
Installation details and completed work




The need
The customer needed help with a receptacle to the right of the sink that was not working. PTX tested that receptacle and found no voltage, then checked the other counter receptacles and found proper voltage there. The different results helped narrow the electrical service call to the affected receptacle and its GFCI protection.
PTX's approach
PTX tripped the two GFCIs and checked their indicator lights. The GFCI that did not show its light was reset and removed from the wall. Testing found power on the line side but not the load side. Further troubleshooting showed that the GFCI was broken, so PTX installed one new GFCI rather than replacing receptacles that were working.
The recorded result
After the new GFCI was installed, PTX tested the receptacles. The receptacle beside the sink and the other checked receptacles were working properly at the end of the recorded work on November 4, 2026.
What this job helps another property owner consider
When one receptacle is not working but nearby counter receptacles still have power, the problem may be limited to a particular GFCI or connection. This job shows the value of having the affected receptacle and related GFCI checked before assuming that broader electrical work is needed.
Frequently asked questions
Questions property decision-makers ask
What did PTX find during this Burnaby electrical service call?
The receptacle to the right of the sink had no voltage, while the other counter receptacles had proper voltage. Testing found power on the GFCI's line side but not its load side, and the recorded work identified the GFCI as broken.