Documented field work

Installation details and completed work

Illuminated rectangular ceiling light in a tiled bathroom above a shower curtain.
afterCompleted bathroom ceiling-light installation.
Two illuminated recessed ceiling lights installed above a tiled bathroom wall, with a shower fixture visible at the right.
afterCompleted recessed lighting installation in a tiled bathroom.

The need: bathroom lights and fan were not working

The main bathroom had no working lights or fan. Four switches were removed for inspection, and the connection on the neutral had a melted marrette with damaged wires. The other bathroom issue involved two lights above the shower that were flickering.

PTX's approach: inspect the connections and repair the recorded faults

The breaker was turned off before the main bathroom connection was re-spliced using copper-aluminum marrettes and copper pigtails. Three switches that were in rough shape were disconnected and removed, then three new switches were installed. In the master bathroom, the trims were removed and the existing non-dimmable bulbs were replaced with two dimmable bulbs. One trim broke after it was accidentally dropped, so PTX returned on October 13 to remove the damaged trim and install two Reno lights.

The recorded result

After the main bathroom connection and switches were repaired, the power was turned back on and the recorded work notes state that everything was working properly. The two master bathroom lights were also recorded as working properly after the bulb replacement. PTX later completed the pot light trim repair at no charge for that time and material.

What this job helps another property owner consider

When bathroom lights, switches or a fan stop working, the issue may be at a connection or switch rather than only at the bulb. This job shows the value of having the affected box and wiring connections inspected before deciding what repair is needed; it is an example, not a diagnosis for another property.

Frequently asked questions

Questions property decision-makers ask

What was repaired during this Vancouver electrical service call?

The recorded work included a damaged neutral connection and incorrect marrettes in the main bathroom switch box, three replacement switches, two replacement dimmable bulbs for flickering master bathroom lights, and a later pot light trim repair.