The need

The customer had a circuit with a tripped breaker and a recently installed GFCI. The breaker was reset successfully, but the GFCI had no voltage when it was checked. This indicated that the breaker reset did not explain the entire issue.

PTX's approach

PTX first reset the tripped breaker. The technician explained that older panels can be stiff when they trip and may need to be pushed fully off before being turned back on. The GFCI was then removed for inspection. The recorded finding was that the hot was on the line side while the neutral was on the load side, so PTX reterminated the GFCI correctly and reinstalled it.

The recorded result

After the GFCI was reinstalled, PTX tested it again and recorded the correct voltage. The work was completed during the electrical service call on September 24, 2026, in Langley City.

What this job helps another property owner consider

A tripped breaker may not be the only issue affecting a circuit. In this recorded Langley City service call, checking the connected GFCI identified an incorrect termination that needed to be corrected before the circuit could be checked again.

Frequently asked questions

Questions property decision-makers ask

What did PTX find during this Langley City electrical service call?

PTX found that the GFCI had been terminated incorrectly: the hot was on the line side and the neutral was on the load side. The GFCI was reterminated correctly and reinstalled.

Was the GFCI checked after the repair?

Yes. PTX tested the GFCI after reinstalling it and recorded the correct voltage.